Skip to Content

Please give us a call.

0909 899 367

Hamilton Air Vietnam — Industrial Cooling Solutions ​

Energy Saving HVLS Fans​

High Volume · Low Speed · Phủ sóng tối đa

Cut facility cooling costs by up to 70% without sacrificing comfort. Our HVLS fans move massive volumes of air at low speed — using less energy than a household appliance to condition spaces that defeat conventional HVAC.

70%
Energy Reduction
7.3m
Max Diameter
2,000m²
Per Fan Coverage
500+
Projects Completed
🏭500+ Industrial Projects
⚡PMSM & BLDC Motors
🛡️IP55 → IP68 Rated
🌍Italy & Taiwan Technology
📐Free Airflow Design

Why Conventional Cooling Fails Large Spaces


Vietnam's tropical climate pushes facilities to run air conditioning around the clock — but HVAC was never designed for open-span industrial spaces.

 Thermal Stratification

Hot air accumulates at ceiling level (up to 10°C warmer than the floor), forcing HVAC systems to work harder and longer to achieve no meaningful comfort improvement at occupant level.

 Unsustainable Energy Bills

A 5,000 m² factory running 10 HVAC units at 20 kW each generates 200 kW of continuous demand — at Vietnamese industrial tariffs, that exceeds $20,000 USD per month in electricity alone.

 HVLS Is the Proven Solution

One 7.3m HVLS fan running at 1.5 kW covers 2,000 m², creates a wind-chill effect of 4–8°C, breaks stratification layers, and allows thermostat setpoint elevation of 4–6°C — all at a fraction of HVAC operating cost.

HVLS Fan

1–2 

kW per fan 

Moves entire air column — eliminates stratification across 2,000 m²

Annual Electricity Saving ​ ​ ​ ​ ​ ​ ​ ​ ​ 30–70%

Conventional HVAC

15–25 

kW per unit 

Cools air at the point of discharge — stratification & hot spots persist

How Energy-Saving

HVLS Fans Work

Four interconnected mechanisms deliver the 70% energy saving most facilities achieve.

🌀
01

High Volume, Low Speed

Large-diameter blades (up to 7.3m) rotate slowly at 40–60 RPM, moving thousands of cubic meters of air per minute without creating uncomfortable turbulence.

🏔️
02

Stratification Elimination

The large air column created pushes hot ceiling air down and cold floor air up, equilibrating temperature across the entire building height within minutes.

❄️
03

Wind Chill Effect

Gentle 1–3 m/s airflow over skin increases evaporative cooling, creating a perceived temperature drop of 4–8°C for occupants without any refrigeration.

⚡
04

HVAC Load Reduction

Thermostat setpoints can be raised 4–6°C with no comfort reduction, translating directly to 30–70% HVAC electricity savings — fully measurable on your utility bill.

The Engine Behind

the Efficiency

Hamilton Air exclusively deploys next-generation PMSM and BLDC motors — engineered for the demands of Vietnamese industrial conditions.

Hamilton Air Standard

PMSM Gearless Motor

Permanent Magnet Synchronous Motor with direct-drive architecture. No gearbox means zero transmission losses, near-silent operation, and a lifespan exceeding 100,000 hours.


  • Efficiency: IE5 Premium
  • Gearbox: None (Direct Drive)
  • Noise Level: <45 dB
  • Maintenance: Near Zero
  • Lifespan: 100,000+ hrs

Taiwan Technology

BLDC Digital Motor

Brushless DC motor with digital drive controller delivering precise variable speed management, intelligent load adaptation, and robust performance in high-humidity environments.

  • Control: Digital VFD
  • Speed Range: 10–100%
  • Display: OLED Digital
  • Humidity Resist.: Class F
  • Efficiency: IE3–IE5

IP Protection Range

All-Environment Protection

Hamilton Air's HERO series offers IP ratings from IP55 to IP68 — the only industrial fan line in Vietnam covering food processing, coastal, heavy industrial, and cleanroom environments.

  • IP55: Standard Industrial
  • IP64: Dust-tight + Splash
  • IP65: Full Dust + Jet Water
  • IP68: Submersion Rated
  • Blade Material: High-Grade Aluminium

Energy-Saving HVLS Fan

Series

Six HVLS series designed for specific industrial conditions — from standard factories to coastal food processing and mega logistics warehouses.

NEW 2025  ·  IP65 New

HERO-6

V380e Series

Hamilton Air — Vietnam






Next-generation 6-blade HVLS

for maximum harsh-environment airflow

The HERO-6 V380e represents the pinnacle of Hamilton Air's HVLS engineering. Its advanced 6-blade aluminium profile generates maximum volumetric airflow while the IP65 motor housing provides complete protection against industrial dust, water jets, and corrosive atmospheres.

  • Maximum airflow output — up to 7.3m diameter coverage
  • IP65 certified: full dust-tight + protected against water jets from any direction
  • PMSM gearless motor — near-zero maintenance over 10-year operational life
  • Precision aluminium alloy blades with aerodynamic high-lift profile
  • Compatible with BMS / smart building control systems
Factory Warehouse  Logistics Food Processing High Humidity


NEW 2025  ·  IP64

HERO-5

V300i Series

Hamilton Air — Vietnam

Hamilton Air's flagship HVLS workhorse. The HERO-5 V300i with IP64 protection is the benchmark for factory and distribution centre installations across Vietnam, combining robust performance with outstanding energy efficiency.

  • 5-blade high-efficiency aluminium profile
  • IP64 rated: dust-tight + protected against splashing water
  • PMSM direct-drive motor — <45 dB noise level
  • Diameter range: 3.0m – 7.3m

NEW 2025  ·  IP55

HERO-8

ADF Series

Hamilton Air — Vietnam

The HERO-8 ADF is Hamilton Air's most powerful airflow solution — purpose-built for mega-warehouses, stadiums, and exhibition centres where single-fan coverage of the largest possible floor area is required.

  • 8-blade airfoils technology
  • Widest single-fan coverage in the Hamilton Air range
  • Reduces HVAC load by up to 70% in high-bay applications
  • IP55 rated for standard industrial environments

NEW 2025  ·  IP55

HERO-6

ADF Series

Hamilton Air — Vietnam

Advanced Distributed Flow technology redistributes airflow across a wider footprint, eliminating hot spots in densely-racked warehouses and open commercial spaces where conventional HVLS fans leave dead zones.

  • Airfoils technology eliminates uneven airflow dead zones
  • Ideal for high-rack warehouse installations
  • Commercial-grade aesthetic for shopping centres & public spaces
  • IP55 rated, BMS-compatible control

Where It Works

Built For Every
Industrial Space

Hamilton Air HVLS fans are deployed across Vietnam's most demanding industrial and commercial environments.

🏭
Manufacturing Factory

Continuous airflow maintains operator comfort at production lines. Reduces heat stress incidents and improves productivity in high-temperature manufacturing environments.

📦
Logistics Warehouse

Single HVLS fan covers entire warehouse bay. Eliminates condensation, reduces pallet damage, and maintains consistent temperature for goods requiring controlled storage conditions.

🏪
Automotive Showroom

Premium airflow without visual intrusion. Large-diameter HVLS fans provide imperceptible, silent air movement that enhances showroom comfort without competing with the vehicles on display.

🍽️
Restaurant & Café

Architectural ceiling fans with HVLS-class airflow. Pandora V150e and V180e series deliver restaurant-grade comfort in open dining spaces without the industrial aesthetic.

🏋️
Sports & Fitness Venues

High-volume low-noise airflow for arenas, gyms, and indoor courts. IP55-rated for high-humidity sports halls where sweat and cleaning water are constant.

🏖️
Resort & Hotel

IP65/IP68 coastal-rated fans for beachside resorts, pool pavilions, and open-air lobby spaces. Salt-air resistant motor housing designed for Vietnam's coastal climate.

Financial Analysis

Calculate Your
ROI

Enter your facility parameters to see projected energy savings and payback period.

Your Facility

Estimated Results
Current HVAC cost 2778M VND/yr
Fans recommended 3 fans
HVLS running cost 62M VND/yr
Net annual saving 1049M VND/yr
Estimated payback 3 months
📉

Reduce HVAC Energy 30–70%

HVLS fans allow HVAC thermostat setpoints to be raised 4–6°C with no occupant comfort impact — directly reducing compressor runtime and electricity consumption.

🔧

Cut HVAC Maintenance Costs

Lower HVAC runtime translates to fewer service hours, longer compressor lifespan, and reduced refrigerant top-up frequency — lowering total maintenance spend by 20–40%.

📦

Reduce Inventory Loss

Consistent air circulation eliminates condensation hot spots that damage packaging, degrade product quality, and create compliance issues in food and pharmaceutical logistics.

👷

Improve Worker Productivity

Research correlates 2–4°C perceived temperature reduction with 5–15% increase in manual labour productivity — a measurable ROI multiplier beyond direct energy savings.

Motor Technology

PMSM, BLDC &
IP Protection

Three technological pillars that make Hamilton Air fans the most energy-efficient and durable HVLS solution in Vietnam.

European Technology

PMSM Gearless Motor

Permanent Magnet Synchronous Motor with direct drive — no gearbox, no brush wear, no lubricant. The highest-efficiency motor architecture available for industrial fan applications.

Efficiency ClassIE4 Premium
GearboxNone (Direct Drive)
Noise Level<45 dB
MaintenanceNear Zero
Lifespan100,000+ hrs
Taiwan Technology

BLDC Digital Motor

Brushless DC motor with digital drive controller delivering precise variable speed management, intelligent load adaptation, and robust performance in high-humidity environments.

ControlDigital VFD
Speed Range10–100%
DisplayOLED Digital
Humidity Resist.Class F
EfficiencyIE3–IE4
IP Protection Range

All-Environment Protection

Hamilton Air's HERO series offers IP ratings from IP55 to IP68 — the only industrial fan line in Vietnam covering food processing, coastal, heavy industrial, and cleanroom environments.

IP55Standard Industrial
IP64Dust-tight + Splash
IP65Full Dust + Jet Water
IP68Submersion Rated
Blade MaterialHigh-Grade Aluminium

Energy Saving HVLS Fans:

The Complete Guide for Vietnam Industry

What Is an HVLS Fan?

HVLS stands for High Volume Low Speed — a category of industrial ceiling fan defined by large blade diameter (typically 2.5m–7.3m) and very low rotational speed (20–70 RPM). Unlike conventional fans that move air at high speed over a small area, HVLS fans move enormous volumes of air gently across an entire facility floor.

A single 7.3m HVLS fan can effectively ventilate and thermally equalize a space of 1,500–2,000 m² — a task that would require dozens of conventional pedestal fans or multiple full HVAC units to achieve equivalent comfort outcomes, at a fraction of the energy cost.

Key Fact: An HVLS fan consuming 1.5 kW can create thermal comfort conditions equivalent to lowering the ambient air temperature by 4–8°C. The same result from air conditioning would require 15–25 kW of compressor power — a 10–17× energy difference.

Why Energy Savings Are So Significant

The energy efficiency of HVLS fans comes from fundamental physics rather than incremental engineering improvement. Moving air mass across a large surface area at low speed is inherently more energy-efficient than cooling that same air mass through refrigeration. The relevant metrics:

  • HVLS fan power consumption: 0.75 kW – 2.5 kW per unit depending on diameter
  • Effective coverage per fan: 1,000 – 2,000 m² of floor area
  • Equivalent HVAC capacity displaced: 3–5 units of 10–20 kW each
  • Resulting energy reduction: 30–70% of HVAC-only operating cost
  • Typical payback period: 12–36 months at standard Vietnamese industrial tariffs

PMSM vs BLDC: Which Motor Technology Is Right for Your Project?

Hamilton Air's HVLS fan range is powered by two classes of next-generation motor — both far superior to the AC induction motors found in legacy industrial fans, but optimized for different operational priorities.

PMSM (Permanent Magnet Synchronous Motor) — deployed in the Hamilton Air HERO series — is a gearless direct-drive motor. The absence of a gearbox eliminates the primary source of mechanical failure in industrial fans. PMSM motors deliver IE4 Premium Efficiency ratings, near-silent operation below 45 dB, and an operational lifespan exceeding 100,000 hours with essentially zero scheduled maintenance.

BLDC (Brushless DC Motor) — used in the Powersky X6 and Sunon Series — offers precise digital speed control, rapid response to variable-demand conditions, and excellent performance in high-humidity environments. BLDC-driven fans with OLED display control panels are particularly suited to facilities with sophisticated building management systems.

HVLS Fan Sizing: How Many Fans Does My Facility Need?

The fundamental sizing rule is straightforward: one 7.3m diameter HVLS fan covers approximately 1,500–2,000 m² of floor area at ceiling heights between 6m and 12m. However, optimal fan count and placement depend on multiple variables:

  • Ceiling height — taller ceilings require more powerful fans or closer spacing
  • Heat load — high-density equipment generates thermal plumes that affect airflow patterns
  • Obstructions — racking systems, mezzanines, and structural columns influence air distribution
  • Occupancy zones — areas with high personnel density may require supplementary coverage
  • Existing HVAC placement — HVLS fans amplify HVAC distribution when correctly co-located

Hamilton Air provides free computational airflow surveys for all industrial projects. Our technical team uses CFD (Computational Fluid Dynamics) modeling to validate fan placement before installation, eliminating the risk of dead zones or inadequate coverage.

Winter Operation: Destratification Mode

HVLS fans deliver significant energy savings in Northern Vietnam's cooler months through destratification — reversing fan rotation to push warm ceiling air (which accumulates at up to 10°C above floor temperature in high-bay facilities) gently back to occupant level. Facilities operating this mode typically achieve 20–35% reduction in heating costs with no additional equipment investment.

Hamilton Air: Vietnam's Premium HVLS Specialist

Hamilton Air has completed more than 500 HVLS projects across Vietnam, serving clients from FDI electronics manufacturers in Binh Duong to resort operators in Da Nang and logistics operators in Ho Chi Minh City. Our technical advisory service begins with a site survey and ends with a commissioned, commissioned installation backed by a full warranty programme.

We represent HVLS and industrial fan brands from Italy (COOLIBRI — Pulsar II, Syncro II), Taiwan (Aeropower — Powersky X6; Sunon — Series 3 & Series 10), and our own Hamilton Air HERO series — giving clients access to the full spectrum of HVLS technology from a single specialist supplier.

Common Questions

Frequently Asked Questions


HVLS fans consume 1–2 kW of electricity while creating a wind chill effect equivalent to lowering the perceived temperature by 4–8°C. This allows facilities to raise thermostat settings by 4–6°C without reducing occupant comfort, reducing HVAC energy consumption by 30–70% depending on the application.

As a general rule, one 7.3m HVLS fan effectively covers approximately 1,500–2,000 m² of floor area. The optimal configuration depends on ceiling height, heat load, occupancy, and airflow patterns. Hamilton Air provides free technical surveys and airflow proposals for all industrial projects.

Most industrial installations achieve full ROI within 18–36 months through reduced HVAC electricity costs, lower HVAC maintenance spend, and reduced equipment downtime from improved air circulation. For facilities operating 16–24 hours daily, ROI can be achieved in under 12 months.


PMSM (Permanent Magnet Synchronous Motor) is a gearless direct-drive motor offering higher efficiency, lower noise, longer lifespan, and near-zero maintenance due to the absence of gears. BLDC (Brushless DC) motors are also highly efficient and digitally controlled, offering precise speed management. Both are far superior to traditional AC induction motors.

Yes. Hamilton Air's HERO-6 V380e Series carries IP65 protection and the HERO-6 X Series is IP68-rated, making them suitable for coastal environments, food processing plants with washdowns, high-humidity manufacturing, and partially-open industrial structures.

Yes. HVLS fans running in reverse (destratification mode) push warm air trapped at ceiling level back down to occupant height, reducing heating costs by 20–35% in cooler months. This is especially valuable in high-ceiling warehouses and logistics facilities in Northern Vietnam during winter.  

Ready to Cut Your
Cooling Costs by 70%?

Our engineering team will survey your facility, model the optimal HVLS configuration, and deliver a full energy savings projection — free of charge.

HAMILTON AIR – SERVICES

CONTACT HAMILTON AIR

Zalo Chat Zalo Business WhatsApp WhatsApp Business Hotline Hotline 0915123860 Đặt Lịch Khảo Sát Đặt Lịch Khảo Sát Liên Hệ Tư Vấn Liên Hệ Tư Vấn