Quality products by HAMILTON AIR
The STRATOS HVLS Ceiling Fan
A single large-diameter fan that moves enormous volumes of air at a gentle, whisper-quiet pace — cooling people, not machines. Ø3.1 m to 5.0 m.
Energy
Saving
HVLS Fans
Cut facility cooling costs by up to 70% without sacrificing comfort. Our HVLS fans move massive volumes of air at low speed — using less energy than a household appliance to condition spaces that defeat conventional HVAC.
Why STRATOS is engineered differently
Plenty of factories sell "big ceiling fans." What separates a premium HVLS fan from a commodity one is the drivetrain, the blade structure and the safety design — the things you don't see in a spec sheet's headline number. Here's what STRATOS gets right.
Zero motor maintenance <39 dB whisper-quiet Forward & reverse (summer/winter) Anodized, corrosion-resistant blades BMS-ready controlGEARLESS
Direct-drive PMSM
A permanent-magnet synchronous motor drives the rotor directly. No gearbox means no gear whine, no oil, no wear parts — and years of sealed, silent running.
RIGID
Embedded airfoils
Five extruded aluminium-magnesium blades lock into the hub with embedded connections — not bolts through the blade face — for a stiff, balanced rotor.
REDUNDANT
Doubled safety
Guy-wire bracing, an independent secondary safety cable, blade retention pins and a reinforced steel mounting plate. Every load path overhead is doubled.
SIMPLE
Single-phase 220V
A variable-frequency drive holds any speed with soft start/stop and draws just 2.6–5.0 A. Install it almost anywhere, with BMS integration on request.
How HVLS Fans
Save Energy
Four interconnected mechanisms that transform air management economics in large spaces.
Large-Diameter Rotation
Blades up to 7.3m in diameter move enormous air volumes at very low RPM — generating a gentle, uniform downdraft across up to 2,000m² of floor area per fan.
Wind Chill Effect
Air movement creates an evaporative cooling sensation equivalent to lowering perceived temperature by 4–8°C — allowing HVAC thermostats to be raised without discomfort.
Destratification
Continuous air column mixing eliminates the temperature gradient between floor and ceiling, forcing HVAC to condition a single, uniform air mass rather than fighting thermal layers.
PMSM Efficiency
Permanent Magnet Synchronous Motors drive the blades at 1–2 kW — less power than a household appliance — while moving air volumes equivalent to dozens of standard fans.
Full specifications — STRATOS four models
Every STRATOS model uses five blades and single-phase 220 V. Pick the diameter to match your ceiling height and the floor area you need to cover; the airflow and coverage figures below are the fastest way to shortlist.
| Parameter | STRATOS-D5000 | STRATOS-D4200 | STRATOS-D3600 | STRATOS-D3100 |
|---|---|---|---|---|
| Diameter | 5000 mm (17 ft) | 4200 mm (14 ft) | 3600 mm (12 ft) | 3100 mm (11 ft) |
| Blades | 5 | 5 | 5 | 5 |
| Weight | 60 kg | 57 kg | 54 kg | 51 kg |
| Power | 0.6 kW | 0.5 kW | 0.4 kW | 0.3 kW |
| Max speed | 70 rpm | 80 rpm | 90 rpm | 100 rpm |
| Max air volume | 7,065 m³/min | 5,306 m³/min | 4,522 m³/min | 3,140 m³/min |
| Power supply | 220V · 1-ph | 220V · 1-ph | 220V · 1-ph | 220V · 1-ph |
| Rated input current | 5.0 A | 3.8 A | 3.0 A | 2.6 A |
| Rated output current | 2.2 A | 1.8 A | 1.3 A | 1.2 A |
| Noise level | <39 dB | <38 dB | <38 dB | <38 dB |
| Wind coverage | Ø20–25 m | Ø17–21 m | Ø15–18 m | Ø13–16 m |
STRATOS — product parameters (all models: 5 blades · 220V single-phase)
Specifications subject to change without notice. For a stamped datasheet against your project conditions, request the engineering document.
D5000 for the biggest halls and highest ceilings · D4200 / D3600 for typical warehouses and workshops · D3100 for lower ceilings, mezzanines and tighter bays.
The energy & HVAC case: why one big fan pays for itself
The strongest argument for STRATOS is on the utility bill. There are two savings mechanisms — the fan's own low draw, and the load it takes off your air-conditioning.
1 · The fan itself sips power
The flagship 5.0 m model peaks at 0.6 kW; the 3.1 m model runs on 0.3 kW. For context, that flagship draws about the same as a household hair-dryer set to low — while moving over 7,000 m³ of air a minute across hundreds of square metres.
2 · It reduces the work your HVAC has to do
Because occupants feel cooler through air movement, you can raise the air-conditioning setpoint by a few degrees and still keep people comfortable — and every degree of setpoint typically trims cooling energy. In heated spaces, winter destratification recovers the warm air trapped at the ceiling instead of paying to reheat the floor. The net effect is a measurable cut in HVAC energy consumption.
Where STRATOS wins
- High ceilings (heat stratifies badly — big savings)
- Large open floors that spot fans can't cover
- Facilities running HVAC most of the year
- Operations that need low noise and low maintenance
Where to think twice
- Very low ceilings under ~4 m (choose a compact HVLS or the smaller diameter)
- Spaces needing focused, high-velocity spot cooling on a machine
- Rooms cut up by walls/racking that block a wide airflow circle
- Sealed cleanrooms with strict directional airflow rules
Expert tip
Ask us for an energy-saving estimate based on your floor area, ceiling height and current HVAC setpoint. We model expected coverage and give you a realistic payback range — not a marketing number.
How to size a STRATOS fan for your space
Sizing an HVLS fan well is engineering, not guesswork. Diameter is driven by ceiling height and the floor area each fan must cover, with clearances that keep the airflow effective and safe.
Step-by-step: the sizing logic we use
The fan needs clearance above and below. Higher ceilings favour larger diameters that can throw air all the way to the floor.
Measure the ceiling height
Racking, mezzanines and partitions break up a fan's circular coverage. We plan around them.
Map the floor area & obstructions
Where do people work, and where does heat build up? Fans go where comfort matters most.
Identify heat sources & occupancy
RUse the Ø13–25 m coverage figures to lay out the minimum number of fans with even overlap.
Match diameter to coverage
Each fan needs a single-phase 220 V supply; decide on wall panel, remote or BMS control.
Confirm power & controls
Built For Every
Industrial Space
Hamilton Air HVLS fans are deployed across Vietnam's most demanding industrial and commercial environments.
Continuous airflow maintains operator comfort at production lines. Reduces heat stress incidents and improves productivity in high-temperature manufacturing environments.
Single HVLS fan covers entire warehouse bay. Eliminates condensation, reduces pallet damage, and maintains consistent temperature for goods requiring controlled storage conditions.
Premium airflow without visual intrusion. Large-diameter HVLS fans provide imperceptible, silent air movement that enhances showroom comfort without competing with the vehicles on display.
Architectural ceiling fans with HVLS-class airflow. Pandora V150e and V180e series deliver restaurant-grade comfort in open dining spaces without the industrial aesthetic.
High-volume low-noise airflow for arenas, gyms, and indoor courts. IP55-rated for high-humidity sports halls where sweat and cleaning water are constant.
IP65/IP68 coastal-rated fans for beachside resorts, pool pavilions, and open-air lobby spaces. Salt-air resistant motor housing designed for Vietnam's coastal climate.